Removing the pipehandler and link tilt from the top drive (while in mast)


1. Drain the oil from the gearbox.

2. Disconnect and cap all tubing, remove the shot pin assembly and the landing collar.

3. Build a support over well center to support the weight of the link adapter.

4. Lower the top drive to the support built in Step 3.

5. Remove the bolts that attach the load stem to the main body.

6. Raise the top drive slowly to separate the link adapter from the main body.

7. Move the link adapter assembly to a clean, safe work area.

8. Orient the assembly with the stem flange up and block the entire assembly so that it is secure in this position.



RETAINER,LANDING COLLAR OEM #118378     EVERGROW #177567

18.118378


PRODUCT CATEGORY

CONTACT US

Add : #11 Tangyan South Road, High-tech Zone, Xi’an, China 
Phone : 86-18991929885
E-mail : sales@linhaievergrow.com
Whatsapp:86-18991929885
LINHAI EVERGROW PETROLEUM EQUIPMENT CO.,LTD.
All manufacturer numbers, names, and descriptions are used for reference purposes only. It is not implied that any listed part is the product of the Original Equipment Manufacturer (OEM). Evergrow is not an OEM authorized reseller of the parts. Evergrow is an accredited ISO9001 facility.

CONTACT US

    Add : #11 Tangyan South Road, High-tech Zone, Xi’an, China 
    Phone : 86-18991929885
    E-mail : sales@linhaievergrow.com
   Whatsapp : 86-18991929885
Copyright  2018  Linhai Evergrow Petroleum Equipment Co.,Ltd. 
Sitemap   |   Support By syoseo.com